Edit Switchboard List

To edit switchboard list project settings, go to

Ribbon: DME: Customization->Project Customization-> dm_elec-old-switchboard-labelP Switchboard List Label Group

Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Project List->Edit Switchboard List

To edit switchboard list master settings, go to

Ribbon: DME: Customization->Master & Standards Customization-> dm_elec-old-panel-labelM Edit Distribution Equipment Master Groups

Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Standards and Master Lists->Edit Distribution Equipment Master Groups

Switchboard List Label Display and Order Dialog Box

customization--switchboard-list-label-display-and-order-dialog-box

See the Common Label and Schedule Information section for more information on using the Move Up and Move Down buttons and the Key, Label, Width, Display, and Schedule Title fields.

Values in the Key column are listed alphabetically below.

AIC: This value is taken from the switchboard definition.

Bus Amps: This value is taken from the switchboard definition.

Callout: The name of the switchboard.

Fault: The total fault in amps of the switchboard.

Feeder Size: This value is taken from the switchboard definition.

IG Bus: This value is taken from the switchboard definition.

List Note 1: This value is taken from the switchboard definition.

List Note 2: This value is taken from the switchboard definition.

List Note 3: This value is taken from the switchboard definition.

Location: This value is taken from the switchboard definition.

Lugs: This value is taken from the switchboard definition.

Main Disconnect Amps: This value is taken from the switchboard definition.

Main Disconnect Type: This value is taken from the switchboard definition.

Mounting: This value is taken from the switchboard definition.

Neutral: This value is taken from the switchboard definition.

Note 1: This value is taken from the switchboard definition.

Note 2: This value is taken from the switchboard definition.

Number of Taps: This value is taken from the switchboard definition.

Short Voltage: The voltage value and poles of the switchboard.

Examples: 208Y/120V 1P, 208V 2P

Total Calculated Amps: The total calculated load in amps of the switchboard.

Total Calculated KVA: The total calculated load in kVA of the switchboard.

Total Connected Amps: The total connected load in amps of the switchboard.

Total Connected KVA: The total connected load in kVA of the switchboard.

Upstream Breaker and Poles: The size of the breaker and number of poles for the switchboard feeder.

Examples: 20/1, 30/3

Upstream Circuit: The circuit the switchboard is fed from.

Upstream Device: The device the switchboard is fed from.

Upstream OCP: This value is taken from the switchboard definition.

Utility Fault: The fault in amps at the switchboard.

Volts: The full voltage value of the switchboard. The volts, poles, and wires will be displayed.

Examples: 208Y/120V 1P 2W, 208V 2P 2W

Volts Only: The voltage value of the switchboard. Only the volts will be displayed. The poles and wires will not be displayed.

Examples: 208Y/120V, 208V