Edit Transfer Switch List

To edit the transfer switch list project settings, go to

Ribbon: DME: Customization->Project Customization-> dm_elec-old-ts-labelP Transfer Switch List Label Group

Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Project List->Edit Transfer Switch List

To edit transfer switch list master settings, go to

Ribbon: DME: Customization->Master & Standards Customization-> dm_elec-old-panel-labelM Edit Distribution Equipment Master Groups

Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Standards and Master Lists->Edit Distribution Equipment Master Groups

Transfer Switch List Label Display and Order Dialog Box

Customization--Labels and Schedules.Transfer Switch List Label Display and Order dialog box

See the Common Label and Schedule Information section for more information on using the Move Up and Move Down buttons and the , Key, Label, Width, Display, and Schedule Title fields.

Values in the Key column are listed alphabetically below.

Amps: This value is taken from the transfer switch definition.

Callout: The name of the transfer switch.

Emergency Feeder Size: This value is taken from the transfer switch definition.

Emergency Upstream Breaker and Poles: The size of the breaker and number of poles for the transfer switch emergency feeder.

Examples: 20/1, 30/3

Emergency Upstream Circuit: The circuit the transfer switch is fed from for emergency power.

Emergency Upstream Device: The device the transfer switch is fed from for emergency power.

Emergency Upstream OCP: This value is taken from the transfer switch definition.

Fault: The total fault in amps of the transfer switch.

IG Bus: This value is taken from the transfer switch definition.

List Note 1: This value is taken from the transfer switch definition.

List Note 2: This value is taken from the transfer switch definition.

List Note 3: This value is taken from the transfer switch definition.

Location: This value is taken from the transfer switch definition.

Lugs: This value is taken from the transfer switch definition.

Mounting: This value is taken from the transfer switch definition.

Neutral: This value is taken from the transfer switch definition.

Normal Feeder Size: This value is taken from the transfer switch definition.

Normal Upstream Breaker and Poles: The size of the breaker and number of poles for the transfer switch normal feeder.

Examples: 20/1, 30/3

Normal Upstream Circuit: The circuit the transfer switch is fed from for normal power.

Normal Upstream Device: The device the transfer switch is fed from for normal power.

Normal Upstream OCP: This value is taken from the transfer switch definition.

Note 1: This value is taken from the transfer switch definition.

Note 2: This value is taken from the transfer switch definition.

Number of Taps: This value is taken from the transfer switch definition.

Short Voltage: The voltage value and poles of the transfer switch.

Examples: 208Y/120V 1P, 208V 2P

Total Calculated Amps: The total calculated load in amps of the transfer switch.

Total Calculated KVA: The total calculated load in kVA of the transfer switch.

Total Connected Amps: The total connected load in amps of the transfer switch.

Total Connected KVA: The total connected load in kVA of the transfer switch.

Type: This value is taken from the transfer switch definition.

Utility Fault: The fault in amps at the transfer switch.

Volts: The full voltage value of the transfer switch. The volts, poles, and wires will be displayed.

Examples: 208Y/120V 1P 2W, 208V 2P 2W

Volts Only: The voltage value of the transfer switch. Only the volts will be displayed. The poles and wires will not be displayed.

Examples: 208Y/120V, 208V