Edit UPS/Phase Inverter List

To edit UPS/phase inverter list project settings, go to

Ribbon: DME: Customization->Project Customization-> dm_elec-old-ups-labelP UPS/Phase Inverter List Label Group

Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Project List->Edit UPS/Phase Inverter List

To edit UPS/phase inverter list master settings, go to

Ribbon: DME: Customization->Master & Standards Customization-> dm_elec-old-panel-labelM Edit Distribution Equipment Master Groups

Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Standards and Master Lists->Edit Distribution Equipment Master Groups

UPS List Label Display and Order Dialog Box

customization--ups-list-label-display-and-order-dialog-box

See the Common Label and Schedule Information section for more information on using the Move Up and Move Down buttons and the Key, Label, Width, Display, and Schedule Title fields.

Values in the Key column are listed alphabetically below.

AIC: This value is taken from the UPS definition.

Bypass Feeder Size: This value is taken from the UPS definition.

Bypass Upstream OCP: This value is taken from the UPS definition.

Bypass Upstream Breaker and Poles: The size of the breaker and number of poles for the UPS bypass feeder.

Examples: 20/1, 30/3

Bypass Upstream Circuit: The circuit the UPS is fed from for bypass power.

Bypass Upstream Device: The device the UPS is fed from for bypass power.

Callout: The name of the UPS.

Efficiency: This value is taken from the UPS definition.

Fault: The total fault in amps of the UPS.

IG Bus: This value is taken from the UPS definition.

Input KVA: This value is taken from the UPS definition.

KVA: This value is taken from the UPS definition.

KW: This value is taken from the UPS definition.

List Note 1: This value is taken from the UPS definition.

List Note 2: This value is taken from the UPS definition.

List Note 3: This value is taken from the UPS definition.

Location: This value is taken from the UPS definition.

Mounting: This value is taken from the UPS definition.

Normal Feeder Size: This value is taken from the UPS definition.

Normal Upstream Breaker and Poles: The size of the breaker and number of poles for the UPS normal feeder.

Examples: 20/1, 30/3

Normal Upstream Circuit: The circuit the UPS is fed from for normal power.

Normal Upstream Device: The device the UPS is fed from for normal power.

Normal Upstream OCP: This value is taken from the UPS definition.

Note 1: This value is taken from the UPS definition.

Note 2: This value is taken from the UPS definition.

Power Factor: This value is taken from the UPS definition.

Short Voltage: The voltage value and poles of the UPS.

Examples: 208Y/120V 1P, 208V 2P

Taps: This value is taken from the UPS definition.

Total Calculated Amps: The total calculated load in amps of the UPS.

Total Calculated KVA: The total calculated load in kVA of the UPS.

Total Connected Amps: The total connected load in amps of the UPS.

Total Connected KVA: The total connected load in kVA of the UPS.

Utility Fault: The fault in amps at the UPS.

Volts: The full voltage value of the UPS. The volts, poles, and wires will be displayed.

Examples: 208Y/120V 1P 2W, 208V 2P 2W

Volts Only: The voltage value of the UPS. Only the volts will be displayed. The poles and wires will not be displayed.

Examples: 208Y/120V, 208V