Insert Egress Photometric Calculation Area

The Insert Egress Photometric Calculation Area command is used to insert a flat area on the drawing where egress foot-candle levels are to be calculated.

To insert an egress area boundary on the drawing, go to

Ribbon: DM Electrical->Point-by-Point Photometrics-> dm_elec-photoEgressBoundary-ribbon Draw Egress Photometric Calculation Area

Pulldown Menu: DM Electrical->Point-by-Point Photometrics->Draw Egress Photometric Calculation Area

Insert Photometric Calculation Area Boundary Dialog Box

point-by-point-photometrics--insert-egress-photometric-calculation-area-boundary-dialog-box

See the Common Photometric Boundary Information section for information about the values in this dialog box.

Inserting the Egress Calculation Area on the Drawing

To insert the calculation area on the drawing, press the OK button. The settings you specified in the dialog box will be used for the area you insert.

You will be prompted to draw the calculation area on the drawing.

Specify first point of calculation area:

Continue entering points on the drawing until the calculation area is complete.

Specify next point of calculation area:

Press ENTER to finish drawing the calculation area.

You will then be prompted to insert the calculation schedule, group the calculation area with another area, or finish the command.

Specify insertion point for calculation schedule or point inside boundary to group with:

Insert Calculation Schedule: To insert a calculation schedule, specify a point on the drawing that is not inside of another calculation area. A calculation schedule will be inserted at the point specified.

Group the Area with Another Group: To group the area with another group, select a point on the drawing that is inside of another calculation area. The two calculation areas will be grouped. If the selected calculation area already has a calculation schedule on the drawing, it will be used as the calculation schedule for the group. If it does not have a calculation schedule, no calculation schedule will be used for the group.

Finish the Command: Press ENTER to finish the command without inserting a calculation schedule or grouping the calculation area with another group. No calculation schedule will be inserted and the calculation area will be in its own separate group.


Page url: http://www.designmaster.biz/docs/elec/index.html?insert_egress_photometric_calculation_area.htm