Insert Indoor Lighting Level Report

The Insert Indoor Lighting Level Report command is used to display the lighting levels in each room in the project.

To insert the indoor lighting level report on the drawing, go to

Ribbon: DM Electrical->Devices-> dm_elec-ltg-indoorLevel Insert Indoor Lighting Level Report

Pulldown Menu: DM Electrical->Light Fixtures->Insert Indoor Lighting Level Report

Indoor Lighting Levels Dialog Box

Light Fixtures--Indoor Lighting Levels dialog box

Schedule Notes: A note that will appear below the schedule when inserted on the drawing.

Maximum Schedule Height: Whether the schedule has a maximum height. This height corresponds to inches on the printed page.

If this is not checked, the schedule will be in a single schedule.

If this is checked, you can specify the maximum height of the schedule. When the schedule exceeds this height, it will be continued in a second schedule next to the first. The label of the second schedule will have the Schedule Title Continued Label option added to it to indicate that it is a continuation of the first schedule. See the Options->Schedules section for more information.

Specify on Drawing: Press this button to specify the Maximum Schedule Height on the drawing. The dialog box will be closed and you will be prompted to specify the height.

Specify maximum schedule height:

The distance that you enter on the drawing will be used as the maximum height. It is simplest to draw a line straight down to where the bottom of the schedule should be located.

Zoom to Schedule After Insertion: If this box is checked, the display will be moved to the schedule location after it has been inserted or updated. Check this box if you are having difficulty locating your schedule on a busy drawing.

Edit Title, Column Labels, and Column Order: Press this button to modify the layout of the schedule on the drawing. See the Edit Indoor Lighting Level Schedule List section for more information.

Inserting or Updating the Report on the Drawing

To insert or update the lighting level report, press the OK button.

Inserting the Report the First Time

If the indoor lighting level report is not currently inserted on the drawing, you will be prompted for the insertion location of the report.

Specify insertion point for indoor lighting level report:

The location you specify will be used as the top-left corner of the report.

Updating the Report Already on the Drawing

If the indoor lighting level report is already inserted on the drawing, it will be updated in its current location.

It is necessary to update the report on the drawing when you make changes to the project schedule. The report will not update automatically.

The indoor lighting level report will also be updated when the Update All Schedules and One-Line Diagram command is run.

If you have manually inserted graphics, such as revision clouds, over the schedule graphic, always be certain to check their location after updating the schedule.