Arc-Flash Shared Parameters

The shared parameters added to distribution equipment related to arc-flash calculations.

Numeric Parameters

Parameter types in this section are set to number unless otherwise noted.

DMEN_ArcFlash_ArcingCurrentMaximum: The maximum arcing current in amps.

DMEN_ArcFlash_ArcingCurrentReduced: The reduced arcing current in amps.

DMEN_ArcFlash_ConductorGap: The conductor gap in inches.

DMEN_ArcFlash_EnclosureDepth: The depth of the enclosure in inches.

DMEN_ArcFlash_EnclosureHeight: The height of the enclosure in inches.

DMEN_ArcFlash_EnclosureWidth: The width of the enclosure in inches.

DMEN_ArcFlash_IncidentEnergyAtMaximumCurrent: The incident energy at maximum arcing current in Joules/cm².

DMEN_ArcFlash_IncidentEnergyAtReducedCurrent: The incident energy at reduced arcing current in Joules/cm².

DMEN_ArcFlash_MaximumIncidentEnergy: The maximum arc-flash incident energy in Joules/cm².

DMEN_ArcFlash_ProtectionBoundaryDistance: The arc-flash-protection boundary distance as a length parameter.

DMEN_ArcFlash_WorkingDistance: The working distance as a length parameter.

Text Parameters

Parameter types in this section are set to text.

DMET_ArcFlash_ArcingCurrentMaximum: The maximum arcing current in amps.

DMET_ArcFlash_ArcingCurrentReduced: The reduced arcing current in amps.

DMET_ArcFlash_Calculate: A Yes or No value that indicates whether the arc-flash is calculated for the distribution equipment. It also is used to indicate whether the distribution equipment should be displayed in the arc-flash schedule. The default arc-flash schedule includes this parameter as a hidden column. Any distribution equipment with the value set to No is not included in the schedule. Pieces of electrical equipment with their Part Type set to Equipment Switch are automatically set to No so they are not displayed in the schedule.

DMET_ArcFlash_ConductorGap_inch: The conductor gap in inches.

DMET_ArcFlash_ConductorGap_mm: The conductor gap in millimeters.

DMET_ArcFlash_ElectrodeConfiguration: The electrode configuration for the distribution equipment.

DMET_ArcFlash_EnclosureDepth_inch: The depth of the enclosure in inches.

DMET_ArcFlash_EnclosureDepth_mm: The depth of the enclosure in millimeters.

DMET_ArcFlash_EnclosureHeight_inch: The height of the enclosure in inches.

DMET_ArcFlash_EnclosureHeight_mm: The height of the enclosure in millimeters.

DMET_ArcFlash_EnclosureWidth_inch: The width of the enclosure in inches.

DMET_ArcFlash_EnclosureWidth_mm: The width of the enclosure in millimeters.

DMET_ArcFlash_IncidentEnergyAtMaximumCurrent_cal: The incident energy at maximum arcing current in calories/cm².

DMET_ArcFlash_IncidentEnergyAtMaximumCurrent_J: The incident energy at maximum arcing current in Joules/cm².

DMET_ArcFlash_IncidentEnergyAtReducedCurrent_cal: The incident energy at reduced arcing current in calories/cm².

DMET_ArcFlash_IncidentEnergyAtReducedCurrent_J: The incident energy at reduced arcing current in Joules/cm².

DMET_ArcFlash_MaximumIncidentEnergy_cal: The maximum arc-flash incident energy in calories/cm².

DMET_ArcFlash_MaximumIncidentEnergy_J: The maximum arc-flash incident energy in Joules/cm².

DMET_ArcFlash_ProtectionBoundaryDistance_ft: The arc-flash-protection boundary distance in feet.

DMET_ArcFlash_ProtectionBoundaryDistance_mm: The arc-flash-protection boundary distance in millimeters.

DMET_ArcFlash_WorkingDistance_ft: The working distance in feet.

DMET_ArcFlash_WorkingDistance_mm: The working distance in millimeters.