Circuit Shared Parameters

The shared parameters added to circuits.

Numeric Parameters

Parameter types in this section are set to number unless otherwise noted.

DMEN_Circuit_ConductorWireArea: The area of the conductor wire as an area parameter. The area is for a single conductor wire. It does not account for parallel runs or the number of poles.

DMEN_Circuit_ConduitArea: The area of the conduit as an area parameter.

DMEN_Circuit_ConduitFill: The conduit fill as a percentage.

DMEN_Circuit_FaultAtDevice: The available fault current at the distribution equipment or branch circuit device connected to the circuit as a current parameter. Includes both the utility fault and motor contributions.

DMEN_Circuit_FaultMotorDirectlyConnected: The fault due to the branch circuit device, or due to motors directly connected to the distribution equipment connected to the circuit as a current parameter.

DMEN_Circuit_FaultMotorTotal: The total fault due to all motors in the system at the distribution equipment or branch circuit device connected to the circuit as a current parameter.

DMEN_Circuit_FaultUtility: The fault from the utility at the distribution equipment or branch circuit device connected to the circuit as a current parameter.

DMEN_Circuit_GroundWireArea: The area of the ground wire as an area parameter.

DMEN_Circuit_Length: The length of the circuit as a length parameter. If multiple devices are on the circuit, the average distance from the distribution equipment to the devices on the circuit will be displayed.

DMEN_Circuit_NeutralWireArea: The area of the neutral wire as an area parameter.

DMEN_Circuit_ParallelRuns: The number of parallel runs.

DMEN_Circuit_Poles: The number of poles.

DMEN_Circuit_VoltageDrop: The voltage drop of the circuit.

Text Parameters

Parameter types in this section are set to text.

DMET_Circuit_ConductorWireSize: The number of parallel runs and the size of the conductor wires.

DMET_Circuit_ConductorWireSizeOnly: The size of the conductor wires.

DMET_Circuit_ConduitFill: The conduit fill as a percentage.

DMET_Circuit_ConduitSize: The size of the conduit.

DMET_Circuit_FaultAtDevice: The available fault current at the distribution equipment or branch circuit device connected to the circuit. A warning is displayed if the fault exceeds the AIC rating of the distribution equipment. Includes both the utility fault and motor contributions.

DMET_Circuit_FaultAtDevice_NoWarnings: The available fault current at the distribution equipment or branch circuit device connected to the circuit. Includes both the utility fault and motor contributions.

DMET_Circuit_FaultMotorDirectlyConnected: The fault due to the branch circuit device, or due to motors directly connected to the distribution equipment connected to the circuit.

DMET_Circuit_FaultMotorTotal: The total fault due to all motors in the system at the distribution equipment connected to the circuit.

DMET_Circuit_FaultUtility: The fault from the utility at the distribution equipment connected to the circuit.

DMET_Circuit_FeederID: The feeder ID used for the circuit on the one-line diagram.

DMET_Circuit_GroundWireSize: The size of the ground wire.

DMET_Circuit_Length_ft: The length of the circuit in feet. If multiple devices are on the circuit, the average distance from the distribution equipment to the devices on the circuit will be displayed.

DMET_Circuit_Length_m: The length of the circuit in meters. If multiple devices are on the circuit, the average distance from the distribution equipment to the devices on the circuit will be displayed.

DMET_Circuit_NeutralWireSize: The size of the neutral wire.

DMET_Circuit_Number: The circuit number.

DMET_Circuit_ParallelRuns: The number of parallel runs.

DMET_Circuit_VoltageDrop: The voltage drop of the circuit.

DMET_Circuit_WireCallout: The wire callout for the circuit using the calculated or specified wire size settings. Wire sizes are separated by a comma and a space.

DMET_Circuit_WireCalloutCompact: The wire callout for the circuit using the calculated or specified wire size settings. Wire sizes are separated by a comma.

DMET_Circuit_WireCalloutHR: The wire callout for the circuit using the calculated or specified wire size settings. Wire sizes are separated by a comma. Some callouts are hidden depending upon the Homerun wire callouts option set in the Project Options command.