The general shared parameters added to distribution equipment. Numeric Parameters Parameter types in this section are set to number unless otherwise noted. DMEN_Panel_LineToLineVoltage: The line-to-line voltage of the distribution equipment as an electrical potential parameter. DMEN_Panel_LineToNeutralVoltage: The line-to-neutral voltage of the distribution equipment as an electrical potential parameter. DMEN_Panel_MainDisconnectFrameSize: The frame size of the main disconnect as a current parameter. DMEN_Panel_MainDisconnectPoles: The number of poles of the main disconnect as an integer parameter. DMEN_Panel_MainDisconnectTripSize: The trip size of the main disconnect as a current parameter. DMEN_Panel_MainDisconnectType: The type of main disconnect as an integer parameter.
Text Parameters Parameter types in this section are set to text. DMET_Panel_BusAmps: The bus amps of the distribution equipment. DMET_Panel_Distribution_System: The distribution system of the distribution equipment. The built-in Revit Distribution System property cannot be included in schedules. Use this parameter to include the value in a schedule. DMET_Panel_FedFrom: The upstream device feeding the distribution equipment. DMET_Panel_FedFrom2: The upstream device connected to the second feeder of the distribution equipment. DMET_Panel_FedFromCircuit: The circuit on the upstream device to which the distribution equipment is connected. DMET_Panel_FedFromCircuit2: The circuit on the upstream device to which the second feeder of distribution equipment is connected. DMET_Panel_LineToLineVoltage: The line-to-line voltage of the distribution equipment. DMET_Panel_LineToNeutralVoltage: The line-to-neutral voltage of the distribution equipment. DMET_Panel_Lugs: The type of lugs specified for the distribution equipment. DMET_Panel_MainDisconnect: The main disconnect type, trip, and frame size, together in a single shared parameter. The numbers listed below are example values.
DMET_Panel_MainDisconnectFrameSize: The frame size of the main disconnect. DMET_Panel_MainDisconnectPoles: The number of poles of the main disconnect. DMET_Panel_MainDisconnectTripSize: The trip size of the main disconnect. DMET_Panel_MainDisconnectType: The type of main disconnect.
DMET_PanelTree_Label: The name of the distribution equipment, indented based upon its position in the model. The indent begins with a period because Revit removes any leading spaces in the value. DMET_PanelTree_SortOrder: A number representing the position of the distribution equipment in the panel tree. When the schedule is sorted by this parameter, the DMET_PanelTree_Label will display the panel tree. DMET_Panel_UpstreamDescription: The description for the distribution equipment as it appears in the circuit description of the upstream panel schedule. DMET_Panel_UpstreamDescription2: The description for the second feeder of the distribution equipment as it appears in the circuit description of the upstream panel schedule. |
Page url:
http://www.designmaster.biz/docs/elecrt/2.0/index.html?panel_shared_parameters.htm
©2013-2022 Design Master Software, Inc |