Modifying Panel Schedules

The wire sizes calculated by Design Master Electrical RT do not use the built-in wire size parameters in Revit MEP. To display the values in your panel schedules, you need to modify your schedule template and change the values that are displayed.

To modify you panel schedules, go to Manage->Panel Schedule Templates->Edit a Template.

Select the schedule to modify and press the Open button.

Use the Modify Panel Schedule Template->Parameters commands to change the values that are displayed in the template.

In the shared parameters pulldown, all the Design Master Electrical RT shared parameters will be at the bottom of the list in the Other section. See the Circuit Shared Parameters section for a list of the shared parameters you can add.

Use the Modify Panel Schedule Template->Columns and Rows commands to add columns as necessary.


Page url: http://www.designmaster.biz/docs/elecrt/index.html?modifying_panel_schedules.htm