Panel Shared Parameters

The general shared parameters added to distribution equipment.

Numeric Parameters

Parameter types in this section are set to number unless otherwise noted.

DMEN_Panel_LineToLineVoltage: The line-to-line voltage of the distribution equipment as an electrical potential parameter.

DMEN_Panel_LineToNeutralVoltage: The line-to-neutral voltage of the distribution equipment as an electrical potential parameter.

DMEN_Panel_MainDisconnectFrameSize: The frame size of the main disconnect as a current parameter.

DMEN_Panel_MainDisconnectTripSize: The trip size of the main disconnect as a current parameter.

Text Parameters

Parameter types in this section are set to text.

DMET_Panel_BusAmps: The bus amps of the distribution equipment.

DMET_Panel_LineToLineVoltage: The line-to-line voltage of the distribution equipment.

DMET_Panel_LineToNeutralVoltage: The line-to-neutral voltage of the distribution equipment.

DMET_Panel_Lugs: The type of lugs specified for the distribution equipment.

DMET_Panel_MainDisconnect: The main disconnect type, trip, and frame size, together in a single shared parameter.

MLO: The main disconnect is main lugs only.
MCB 100A: The main disconnect is a main circuit breaker with the frame and trip the same size.
MCB 60AT, 100AF: The main disconnect is a main circuit breaker with different frame and trip sizes. The trip size is labeled with AT (for "amps trip") and the frame size is labeled with AF (for "amps frame").
FS 100A: The main disconnect is a fused switch with the frame and trip the same size.
FS 60AT, 100AF: The main disconnect is a fused switch with different frame and trip sizes. The trip size is labeled with AT (for "amps trip") and the frame size is labeled with AF (for "amps frame").

DMET_Panel_MainDisconnectFrameSize: The frame size of the main disconnect.

DMET_Panel_MainDisconnectTripSize: The trip size of the main disconnect.

DMET_Panel_MainDisconnectType: The type of main disconnect.

MLO: The main disconnect is main lugs only.
MCB: The main disconnect is a main circuit breaker.
FS: The main disconnect is a fused switch.

DMET_PanelTree_Label: The name of the distribution equipment, indented based upon its position in the one-line. The indent begins with a period because Revit removes any leading spaces in the value.

DMET_PanelTree_SortOrder: A number representing the position of the distribution equipment in the panel tree. When the schedule is sorted by this parameter, the DMET_PanelTree_Label will display the panel tree.