Edit Egress Photometric Area Schedule List |
Up Previous Next |
The Edit Egress Photometric Area Schedule List commands are used to modify the labels that appear on egress photometric calculation area schedules on the drawing. Each row that is displayed is included as a row in the schedule. They do not correspond to columns like in other schedules. To set the width of the columns, use the two special values, Label Column Width and Value Column Width. To edit the egress photometric area schedule project settings, go to Ribbon: DME: Customization->Project Customization-> Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Project List->Edit Egress Photometric Area Schedule Project List To edit the egress photometric area schedule standards settings, go to Ribbon: DME: Customization->Master & Standards Customization-> Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Standards and Master Lists->Edit Egress Photometric Area Schedule Standards List Egress Photometric Schedule Label Display and Order Dialog Box See the Common Label and Schedule Information section for more information about using the Move Up and Move Down buttons and the Key, Label, Width, Display, and Schedule Title fields. Values in the Key column are listed alphabetically below. Average Illuminance: The average illuminance value in the photometric calculation area. Average to Maximum Illuminance Ratio: The Average Illuminance divided by the Maximum Illuminance. Average to Maximum Vertical Illuminance Ratio: The Average Vertical Illuminance divided by the Maximum Vertical Illuminance. Average to Minimum Illuminance Ratio: The Average Illuminance divided by the Minimum Illuminance. Average to Minimum Vertical Illuminance Ratio: The Average Vertical Illuminance divided by the Minimum Vertical Illuminance. Average Vertical Illuminance: The average vertical illuminance value in the photometric calculation area. Label Column Width: The width of the label column in the schedule. Maximum Illuminance: The maximum illuminance value in the photometric calculation area. Maximum to Average Illuminance Ratio: The Maximum Illuminance divided by the Average Illuminance. Maximum to Average Vertical Illuminance Ratio: The Maximum Vertical Illuminance divided by the Average Vertical Illuminance. Maximum to Minimum Illuminance Ratio: The Maximum Illuminance divided by the Minimum Illuminance. Maximum to Minimum Vertical Illuminance Ratio: The Maximum Vertical Illuminance divided by the Minimum Vertical Illuminance. Maximum Vertical Illuminance: The maximum vertical illuminance value in the photometric calculation area. Minimum Illuminance: The minimum illuminance value in the photometric calculation area. Minimum to Average Illuminance Ratio: The Minimum Illuminance divided by the Average Illuminance. Minimum to Average Vertical Illuminance Ratio: The Minimum Vertical Illuminance divided by the Average Vertical Illuminance. Minimum to Maximum Illuminance Ratio: The Minimum Illuminance divided by the Maximum Illuminance. Minimum to Maximum Vertical Illuminance Ratio: The Minimum Vertical Illuminance divided by the Maximum Vertical Illuminance. Minimum Vertical Illuminance: The minimum vertical illuminance value in the photometric calculation area. Value Column Width: The width of the value column in the schedule. |
Page url:
http://www.designmaster.biz/docs/elec/index.html?edit_egress_photometric_schedule.htm
©2012-2023 Design Master Software, Inc |