Edit Enclosed Breaker / Disconnect List |
Up Previous Next |
To edit enclosed breaker and disconnect list project settings, go to Ribbon: DME: Customization->Project Customization-> Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Project List->Edit Enclosed Breaker / Disconnect List To edit enclosed breaker and disconnect list master settings, go to Ribbon: DME: Customization->Master & Standards Customization-> Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Standards and Master Lists->Edit Distribution Equipment Master Groups Enclosed Breaker List Label Display and Order Dialog Box See the Common Label and Schedule Information section for more information about using the Move Up and Move Down buttons and the Key, Label, Width, Display, and Schedule Title fields. Values in the Key column are listed alphabetically below. AIC: This value is taken from the enclosed breaker definition. Breaker Bus Amps: This value is taken from the enclosed breaker definition. Callout: The name of the enclosed breaker. Fault: The total fault in amps at the enclosed breaker, including the fault from the utility and the fault from any motors in the system. Feeder Size: This value is taken from the enclosed breaker definition. Frame Size: This value is taken from the enclosed breaker definition. List Note 1: This value is taken from the enclosed breaker definition. List Note 2: This value is taken from the enclosed breaker definition. List Note 3: This value is taken from the enclosed breaker definition. Location: This value is taken from the enclosed breaker definition. Lugs: This value is taken from the enclosed breaker definition. Manufacturer: This value is taken from the enclosed breaker definition. Model: This value is taken from the enclosed breaker definition. Mounting: This value is taken from the enclosed breaker definition. NEMA: This value is taken from the enclosed breaker definition. Note 1: This value is taken from the enclosed breaker definition. Note 2: This value is taken from the enclosed breaker definition. Number of Taps: This value is taken from the enclosed breaker definition. Short Voltage: The voltage value and poles of the enclosed breaker. Examples: 208Y/120V 1P, 208V 2P Total Calculated Amps: The total calculated load in amps of the enclosed breaker. Total Calculated KVA: The total calculated load in kVA of the enclosed breaker. Total Connected Amps: The total connected load in amps of the enclosed breaker. Total Connected KVA: The total connected load in kVA of the enclosed breaker. Type: This value is taken from the enclosed breaker definition. Upstream Breaker and Poles: The size of the breaker and number of poles for the enclosed breaker feeder. Examples: 20/1, 30/3 Upstream Circuit: The circuit to which the enclosed breaker is connected on the upstream device. Upstream Device: The upstream device to which the enclosed breaker is connected. Upstream OCP: This value is taken from the enclosed breaker definition. Utility Fault: The utility fault in amps at the enclosed breaker. Use this column instead of the Fault column if you do not want to include motor contributions. Volts: The full voltage value of the enclosed breaker. The volts, poles, and wires will be displayed. Examples: 208Y/120V 1P 2W, 208V 2P 2W Volts Only: The voltage value of the enclosed breaker. Only the volts will be displayed. The poles and wires will not be displayed. Examples: 208Y/120V, 208V |
Page url:
http://www.designmaster.biz/docs/elec/index.html?edit_enclosed_breaker_disconnect_list.htm
©2012-2023 Design Master Software, Inc |