Edit Meter Center List |
Up Previous Next |
To edit meter center list project settings, go to Ribbon: DME: Customization->Project Customization-> Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Project List->Edit Meter Center List To edit meter center list master settings, go to Ribbon: DME: Customization->Master & Standards Customization-> Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Standards and Master Lists->Edit Distribution Equipment Master Groups Meter Center List Label Display and Order Dialog Box See the Common Label and Schedule Information section for more information about using the Move Up and Move Down buttons and the Key, Label, Width, Display, and Schedule Title fields. Values in the Key column are listed alphabetically below. AIC: This value is taken from the meter center definition. Bus Amps: This value is taken from the meter center definition. Callout: The name of the meter center. Fault: The total fault in amps at the meter center, including the fault from the utility and the fault from any motors in the system. Feeder Size: This value is taken from the meter center definition. IG Bus: This value is taken from the meter center definition. List Note 1: This value is taken from the meter center definition. List Note 2: This value is taken from the meter center definition. List Note 3: This value is taken from the meter center definition. Location: This value is taken from the meter center definition. Lugs: This value is taken from the meter center definition. Main Disconnect Amps: This value is taken from the meter center definition. Main Disconnect Type: This value is taken from the meter center definition. Manufacturer: This value is taken from the meter center definition. Model: This value is taken from the meter center definition. Mounting: This value is taken from the meter center definition. NEMA: This value is taken from the meter center definition. Neutral: This value is taken from the meter center definition. Note 1: This value is taken from the meter center definition. Note 2: This value is taken from the meter center definition. Number of Taps: This value is taken from the meter center definition. Short Voltage: The voltage value and poles of the meter center. Examples: 208Y/120V 1P, 208V 2P Total Calculated Amps: The total calculated load in amps of the meter center. Total Calculated KVA: The total calculated load in kVA of the meter center. Total Connected Amps: The total connected load in amps of the meter center. Total Connected KVA: The total connected load in kVA of the meter center. Upstream Breaker and Poles: The size of the breaker and number of poles for the meter center feeder. Examples: 20/1, 30/3 Upstream Circuit: The circuit to which the meter center is connected on the upstream device. Upstream Device: The upstream device to which the meter center is connected. Upstream OCP: This value is taken from the meter center definition. Utility Fault: The utility fault in amps at the meter center. Use this column instead of the Fault column if you do not want to include motor contributions. Volts: The full voltage value of the meter center. The volts, poles, and wires will be displayed. Examples: 208Y/120V 1P 2W, 208V 2P 2W Volts Only: The voltage value of the meter center. Only the volts will be displayed. The poles and wires will not be displayed. Examples: 208Y/120V, 208V |
Page url:
http://www.designmaster.biz/docs/elec/index.html?edit_meter_center_list.htm
©2012-2023 Design Master Software, Inc |