Edit UPS / Phase Inverter List |
Up Previous Next |
To edit UPS and phase inverter list project settings, go to Ribbon: DME: Customization->Project Customization-> Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Project List->Edit UPS / Phase Inverter List To edit UPS and phase inverter list master settings, go to Ribbon: DME: Customization->Master & Standards Customization-> Pulldown Menu: DM Electrical->Customization->Labels and Schedules->Standards and Master Lists->Edit Distribution Equipment Master Groups UPS List Label Display and Order Dialog Box See the Common Label and Schedule Information section for more information about using the Move Up and Move Down buttons and the Key, Label, Width, Display, and Schedule Title fields. Values in the Key column are listed alphabetically below. AIC: This value is taken from the UPS definition. Bypass Feeder Size: This value is taken from the UPS definition. Bypass Upstream OCP: This value is taken from the UPS definition. Bypass Upstream Breaker and Poles: The size of the breaker and number of poles for the UPS bypass feeder. Examples: 20/1, 30/3 Bypass Upstream Circuit: The circuit to which the UPS is connected on the upstream device for bypass power. Bypass Upstream Device: The upstream device to which the UPS is connected for bypass power. Callout: The name of the UPS. Efficiency: This value is taken from the UPS definition. Fault: The total fault in amps at the UPS, including the fault from the utility and the fault from any motors in the system. IG Bus: This value is taken from the UPS definition. Input KVA: This value is taken from the UPS definition. Input Short Voltage: The input voltage value and poles of the UPS. Examples: 208Y/120V 1P, 208V 2P Input Volts: The full input voltage value of the UPS. The volts, poles, and wires will be displayed. Examples: 208Y/120V 1P 2W, 208V 2P 2W Input Volts Only: The input voltage value of the UPS. Only the volts will be displayed. The poles and wires will not be displayed. Examples: 208Y/120V, 208V KVA: This value is taken from the UPS definition. KW: This value is taken from the UPS definition. List Note 1: This value is taken from the UPS definition. List Note 2: This value is taken from the UPS definition. List Note 3: This value is taken from the UPS definition. Location: This value is taken from the UPS definition. Manufacturer: This value is taken from the UPS definition. Model: This value is taken from the UPS definition. Mounting: This value is taken from the UPS definition. NEMA: This value is taken from the UPS definition. Normal Feeder Size: This value is taken from the UPS definition. Normal Upstream Breaker and Poles: The size of the breaker and number of poles for the UPS normal feeder. Examples: 20/1, 30/3 Normal Upstream Circuit: The circuit to which the UPS is connected on the upstream device for normal power. Normal Upstream Device: The upstream device to which the UPS is connected normal power. Normal Upstream OCP: This value is taken from the UPS definition. Note 1: This value is taken from the UPS definition. Note 2: This value is taken from the UPS definition. Output Short Voltage: The output voltage value and poles of the UPS. Examples: 208Y/120V 1P, 208V 2P Output Volts: The full output voltage value of the UPS. The volts, poles, and wires will be displayed. Examples: 208Y/120V 1P 2W, 208V 2P 2W Output Volts Only: The output voltage value of the UPS. Only the volts will be displayed. The poles and wires will not be displayed. Examples: 208Y/120V, 208V Power Factor: This value is taken from the UPS definition. Taps: This value is taken from the UPS definition. Total Calculated Amps: The total calculated load in amps of the UPS. Total Calculated KVA: The total calculated load in kVA of the UPS. Total Connected Amps: The total connected load in amps of the UPS. Total Connected KVA: The total connected load in kVA of the UPS. Utility Fault: The utility fault in amps at the UPS. Use this column instead of the Fault column if you do not want to include motor contributions. |
Page url:
http://www.designmaster.biz/docs/elec/index.html?edit_ups_list.htm
©2012-2023 Design Master Software, Inc |