The section describes what is printed when Print Heating Detail is checked in the Print Load Calculations dialog box.

Heating Load Details - System and Room
The Heating Loads Details - System and Room table lists each room and zone in the project and a breakdown of the heating loads by type.
Each load lists two values. The first is the load in Btu/h, the second is the load as a percentage of the total heating load.

Location: All of the zones and rooms in the project. Rooms and zones that are part of a zone are indented and listed below the parent zone.
Plenum: The plenum cooling load.
Based upon the following fields in the Query Wall command:
Based upon the following fields in the Edit Rooms and Room Project Schedule commands:
Based upon the following fields in the Zone List command:
Based upon the following fields in the Floor List command:
Based upon the following fields in the Project Info command:
• | OSA Low Temperature Dry Bulb |
Roof: The roof cooling load.
Based upon the following fields in the Edit Rooms and Room Project Schedule commands:
Based upon the following fields in the Zone List command:
Based upon the following fields in the Floor List command:
Based upon the following fields in the Project Info command:
• | OSA Low Temperature Dry Bulb |
Wall: The wall cooling load.
Based upon the following fields in the Query Wall command:
• | Heat Transfer and Solar Gain (Wall) |
• | Door Percentage / Area / Complex |
Based upon the following fields in the Edit Rooms and Room Project Schedule commands:
Based upon the following fields in the Zone List command:
Based upon the following fields in the Project Info command:
• | OSA Low Temperature Dry Bulb |
Glass: The glass cooling load.
Based upon the following fields in the Query Wall command:
• | Heat Transfer but no Solar Gain (Partition) / Heat Transfer and Solar Gain (Wall) |
• | Glass Percentage / Area / Complex |
Based upon the following fields in the Edit Rooms and Room Project Schedule commands:
Based upon the following fields in the Zone List command:
Based upon the following fields in the Project Info command:
• | OSA Low Temperature Dry Bulb |
Slab: The slab cooling load.
Based upon the following fields in the Query Wall command:
Based upon the following fields in the Project Info command:
• | Floor Heat Loss Coefficient |
Horizontal Partitions: The cooling load from floor and ceiling partitions.
Based upon the following fields in the Edit Rooms and Room Project Schedule commands:
• | Floor / Ceiling Partition |
Based upon the following fields in the Zone List command:
Based upon the following fields in the Floor List command:
• | Floor / Ceiling Partition |
Based upon the following fields in the Project Info command:
• | OSA Low Temperature Dry Bulb |
Vertical Partitions: The cooling load from wall partitions.
Based upon the following fields in the Query Wall command:
• | Heat Transfer but no Solar Gain (Partition) |
Based upon the following fields in the Edit Rooms and Room Project Schedule commands:
Based upon the following fields in the Zone List command:
Based upon the following fields in the Floor List command:
Based upon the following fields in the Project Info command:
• | OSA Low Temperature Dry Bulb |
Ventilation: The sensible ventilation cooling load.
Based upon the following fields in the Edit Rooms and Room Project Schedule commands:
Based upon the following fields in the Zone List command:
• | Tempered Low Temperature |
Based upon the following fields in the Project Info command:
• | Ventilation Calculation Method |
• | Maximum Room Ventilation Percentage |
• | OSA Low Temperature Dry Bulb |
Infiltration: The sensible infiltration cooling load.
Based upon the following fields in the Edit Rooms and Room Project Schedule commands:
Based upon the following fields in the Zone List command:
Based upon the following fields in the Project Info command:
• | OSA Low Temperature Dry Bulb |
|