The 90-90 Vertical at Pipe Connection command is used to insert a connecting pipe that rises or drops from the elevation of the pipe to the elevation of the fixture. The connecting pipe then goes toward the fixture at a 90-degree angle to the pipe and turns 90 degrees to connect to the fixture. To make a 90-90 vertical connection at the pipe, go to Ribbon: DM Plumbing->Fixtures-> Pulldown Menu: DM Plumbing->Fixtures->90-90 Vertical at Pipe Connection You will be prompted to identify which fixture to connect to a pipe. Select fixture to connect: You will then be prompted to select the pipe to which the fixture will be connected. Select pipe at connection point: The fixture and the pipe will be connected.
|