Edit Egress Photometric Line Schedule List

The Edit Egress Photometric Line Schedule List commands are used to modify the labels that appear on egress photometric calculation line schedules on the drawing.

warning

Each row that is displayed is included as a row in the schedule. They do not correspond to columns like in other schedules. To set the width of the columns, use the two special values, Label Column Width and Value Column Width.

To edit the egress photometric line schedule project settings, go to
Ribbon: DME: Customization→Project Customization→  Egress Photometric Line Schedule Label Group
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Project List→Edit Egress Photometric Line Schedule Project List

To edit the egress photometric line schedule standards settings, go to
Ribbon: DME: Customization→Master & Standards Customization→  Egress Photometric Line Schedule Label Group
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Standards and Master Lists→Edit Egress Photometric Line Schedule Standards List

Egress Photometric Line Schedule Label Display and Order Dialog Box

See the Common Label and Schedule Information section for more information about using the and buttons and the Key ☰, Label, Width, Justification ▾, and ☐ Display fields.

Values in the Key ☰ column are listed alphabetically below.

  •  Average Illuminance The average illuminance value along the photometric calculation line, including vertical illuminance levels if they are enabled.

  •  Average to Maximum Illuminance Ratio Equal to AverageIlluminanceMaximumIlluminanceAverage\>Illuminance \over Maximum\>Illuminance.

  •  Average to Minimum Illuminance Ratio Equal to AverageIlluminanceMinimumIlluminanceAverage\>Illuminance \over Minimum\>Illuminance.

  •  Label Column Width The width of the label column in the schedule.

  •  Maximum Illuminance The maximum illuminance value along the photometric calculation line, including vertical illuminance levels if they are enabled.

  •  Maximum to Average Illuminance Ratio Equal to MaximumIlluminanceAverageIlluminanceMaximum\>Illuminance \over Average\>Illuminance.

  •  Maximum to Minimum Illuminance Ratio Equal to MaximumIlluminanceMinimumIlluminanceMaximum\>Illuminance \over Minimum\>Illuminance.

  •  Minimum Illuminance The minimum illuminance value along the photometric calculation line, including vertical illuminance levels if they are enabled.

  •  Minimum to Average Illuminance Ratio Equal to MinimumIlluminanceAverageIlluminanceMinimum\>Illuminance \over Average\>Illuminance.

  •  Minimum to Maximum Illuminance Ratio Equal to MinimumIlluminanceMaximumIlluminanceMinimum\>Illuminance \over Maximum\>Illuminance.

  •  Value Column Width The width of the value column in the schedule.