Skip to main content

Edit Transformer List

To edit transformer list project settings, go to
Ribbon: DME: Customization→Project Customization→ Transformer List Label Group icon Transformer List Label Group
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Project List→Edit Transformer List

To edit transformer list master settings, go to
Ribbon: DME: Customization→Master & Standards Customization→ ![Edit Distribution Equipment Master Groups(edit-distribution-equipment-master-groups.md) icon Edit Distribution Equipment Master Groups
Pulldown Menu: DM Electrical→Customization→Labels and Schedules→Standards and Master Lists→Edit Distribution Equipment Master Groups

Transformer List Label Display and Order Dialog Box​

Customization xfmr list label display and order dialog box

Visit the Common Label and Schedule Information section for more information about using the and buttons and the Key ☰, Label, Width, Justification ▾, and ☐ Display fields.

Values in the Key ☰ column are listed alphabetically below.

  •  AIC This value is taken from the transformer definition.

  •  Callout The name of the transformer.

  •  Fault The total fault in amps at the transformer, including the fault from the utility and the fault from any motors in the system.

  •  Feeder Size This value is taken from the transformer definition.

  •  Impedance The impedance of the transformer.

  •  KRated This value is taken from the transformer definition.

  •  List Note 1 This value is taken from the transformer definition.

  •  List Note 2 This value is taken from the transformer definition.

  •  List Note 3 This value is taken from the transformer definition.

  •  Location This value is taken from the transformer definition.

  •  Manufacturer This value is taken from the transformer definition.

  •  Model This value is taken from the transformer definition.

  •  NEMA This value is taken from the transformer definition.

  •  Note 1 This value is taken from the transformer definition.

  •  Note 2 This value is taken from the transformer definition.

  •  Number of Lugs This value is taken from the transformer definition.

  •  Primary Short Voltage The primary voltage value and poles of the transformer.

    Examples: 208Y/120V 1P, 208V 2P

  •  Primary Volts The full primary voltage value of the transformer. The volts, poles, and wires will be displayed.

    Examples: 208Y/120V 1P 2W, 208V 2P 2W

  •  Primary Volts Only The primary voltage value of the transformer. Only the volts will be displayed. The poles and wires will not be displayed.

    Examples: 208Y/120V, 208V

  •  Secondary Short Voltage The secondary voltage value and poles of the transformer.

    Examples: 208Y/120V 1P, 208V 2P

  •  Secondary Volts The full secondary voltage value of the transformer. The volts, poles, and wires will be displayed.

    Examples: 208Y/120V 1P 2W, 208V 2P 2W

  •  Secondary Volts Only The secondary voltage value of the transformer. Only the volts will be displayed. The poles and wires will not be displayed.

    Examples: 208Y/120V, 208V

  •  Total Calculated Amps The total calculated load in amps of the transformer.

  •  Total Calculated KVA The total calculated load in kVA of the transformer.

  •  Total Connected Amps The total calculated load in amps of the transformer.

  •  Total Connected KVA The total calculated load in kVA of the transformer.

  •  Upstream Breaker and Poles The size of the breaker and number of poles for the transformer feeder.

    Examples: 20/1, 30/3

  •  Upstream Circuit The circuit to which the transformer is connected on the upstream device.

  •  Upstream Device The upstream device to which the transformer is connected.

  •  Upstream OCP This value is taken from the transformer definition.

  •  Utility Fault The utility fault in amps at the transformer.

    tip

    Use this column instead of the Fault column if you do not want to include motor contributions.

  •  XFMR KVA This value is taken from the transformer definition.