Exporting Light Fixtures or Diffusers for Reflected Ceiling Plan

Sunday, May 11th, 2014

Q: What is the best way to create a drawing with my light fixtures or diffusers that I can send to the architect for his reflected ceiling plan?

A: Use the Copy Drawing and Remove Links to Database command.

Ribbon: DM Electrical/HVAC->Utilities-> dm_dm-util ->Copy Drawing and Remove Links to Database

Pulldown Menu: DM Electrical/HVAC->Utilities->Copy Drawing and Remove Links to Database

Erase everything from the drawing except for the light fixtures or diffusers you want to send to the architect.

The copy command creates an exact copy of the drawing that is not connected to the project database. Deleting devices from the drawing will not remove them from the database. You are free to make all of the changes necessary for the drawing you want to send to the architect without having to worry about what will happen to your database.

Related Articles

Filter by
Post Page
HVAC Load Calculations Light Fixtures Electrical Rooms Diffusers Electrical
Sort by

Partition Above and Below Floor

Rooms and floors can be defined as having either a floor or ceiling partition, but not both. Fortunately, there is a workaround.

14

COMcheck Lighting Export

You can use the Export to COMcheck command to export some lighting information in Design Master Electrical to a COMcheck file.

8

Indoor Lighting Coefficient of Utilization

The CU is calculated using the IES file attached to the light fixture if possible; otherwise, a default value of 0.7 is used.

8

Diffuser Face Dimensions

You can set the size of diffusers using three parameters in the diffuser schedule, available in the Face Dimensions section of the dialog box.

8

Light Fixture Cutoffs and Shields

Design Master does not have a way to configure light fixture cutoffs and shields, but you can approximate them using the Insert Solid commands.

0

Room Data and Photometrics Show Different Foot-candle Values

Different values for room and point-by-point foot-candle calculations are a result of different calculation methods.

0

Products

Electrical for Revit

Electrical for AutoCAD

HVAC for AutoCAD

Photometrics for AutoCAD

Support

Contact Support

Install & Update Instructions

Online Training

Knowledge Base

User Manuals

Tutorials

Release Notes

Downloads

Wish List

Remote Support

Company

About

Customer Stories

Awards

Newsletter

Blog

Pricing

Electrical for Revit

Electrical for AutoCAD

HVAC for AutoCAD

Photometrics for AutoCAD

Free Trial

Electrical for Revit

Electrical for AutoCAD

HVAC for AutoCAD

Photometrics for AutoCAD

©2001-2019, Design Master Software, Inc